VDC storage — model and architecture

What it is​

VDC storage (Unified Storage) is block storage that belongs to a single virtual data center (VDC) and is exported to external hosts over iSCSI. The storage uses a cluster pool: vStack Center creates a root ZFS dataset on the pool and associates it with the VDC. Volumes are created inside this dataset, count against their VDC's storage quota, and are exported as LUNs.

The model is limited and predictable: one storage instance per VDC, one pool for that storage, and one iSCSI target. These strict constraints simplify the main operational question: "Who owns this volume, and who can see it?" The answer is always unambiguous, because a volume has exactly one VDC owner and is exported to exactly one initiator group.

Storage components​

The entities form a chain from hardware to the consumer. The pool provides space, the root dataset isolates the VDC's space, the volume is the unit exported, the target and LUN provide access, and initiator and portal groups define who can connect and through which addresses.

EntityWhat it isOwnership scope
PoolThe cluster's ZFS pool that hosts the storage root datasetCluster
Root datasetA dataset in the form <пул>/<имя>; the name contains 1–63 characters: lowercase Latin letters, digits, periods, and hyphensOne VDC
VolumeA zvol with the full name <пул>/.vol/<имя>; the size is specified in GB, and the default block size is 32768One VDC
iSCSI targetAn access point with an IQN in the form iqn.2024-01.io.vstack:<имя хранилища>One VDC
LUNA number in 0..255 under which the volume is visible on the targetOne target
Portal groupA set of "address + TCP port" pairs on which the target listensOne pool
PortalAn IP:port pair within a group. It is not managed as a separate object — portals are defined by the group's membershipPortal group
Initiator groupA list of initiator IQNs and authorized networks in CIDR notationOne VDC
CHAP auth groupA set of credentials for iSCSI password protectionOne VDC

The storage name is not merely a label: the target IQN is derived from it. The name segment of the root dataset after / is appended to the iqn.2024-01.io.vstack: prefix. Storage names must therefore be unique within the cluster — otherwise, the second target cannot be created.

How operations work​

vStack Center does not access the pool directly. Storage commands are sent to the SAN controller of the pool that hosts the root dataset. This causes differences in interface behavior that are important to understand — they determine when you see the result.

Operation classInterface behaviorExamples
Reading stored recordsResponds immediately using vStack Center recordsStorage summary, volume list, cluster access overview
Reading live metricsQueries the SAN controller; if it is unavailable, leaves the live fields empty but opens the pageVolume card, current storage capacity
ChangeWaits for confirmation from the pool controller and keeps the progress indicator displayedEnabling storage, creating a portal group
Sequence of changesWaits for the entire sequence of steps on the controller to completeMapping and unmapping a volume

Records are written upon confirmation. If the controller rejects the operation, no group, target, or volume appears in vStack Center — the reason for rejection is passed through from the controller unchanged. The reverse is also true: an object in the list means that the controller confirmed the operation. These objects have no intermediate "creating" state.

Deletion does have an intermediate state. Starting with 3.1.0, interrupted storage removal is shown as a separate state: it indicates that VDC deletion must be run again — previously, such storage appeared to be enabled and healthy. Successful removal clears this state.

Model invariants​

Some constraints are built into the model and checked before contacting the controller. Knowing these rules saves time when investigating failures.

InvariantWhat happens if it is violated
One storage instance per VDCEnabling it again is rejected with code -45007
One pool per storage instanceThe pool is taken from the VDC storage and cannot be selected
One target per VDCConfiguring iSCSI again is rejected with code -45014
The volume name is unique within the VDC storageA name already in use is rejected with code -45018
A volume is exported to exactly one initiator groupAlready mapped — code -45027
The LUN number is available on the targetA number already in use — code -45029
A portal group is immutableIts membership cannot be edited: create a new group instead
One CHAP auth group per targetAssigning a new group replaces the previous one

Capacity and quota​

VDC storage capacity equals the VDC's storage quota — the storage has no separate limit. In the storage summary, the quota appears in the Capacity field of the Properties card. The Storage column on the Virtual Data Centers screen shows used space across all VDCs; the limit itself is edited in the VDC settings using the Storage (GB) field.

The quota covers all space used by the VDC, not just storage volumes: virtual machine disks and previously created volumes are added together. The check runs before contacting the controller and under a lock on the VDC — two concurrent requests cannot jointly bypass the limit. If the requested size does not fit, the operation is rejected with code -45017, and the message shows the requested and available space.

Feature flag​

The entire domain is gated by the feature.unified_storage flag in the cluster options. The flag is disabled by default. While it is disabled, any storage operation is rejected after the privilege check with code -45001 and the message "Unified Storage feature is disabled". The Cluster master role does not bypass the flag.

Who can see what​

The domain is divided into cluster and VDC levels. Enabling storage and creating and deleting portal groups are reserved for the Cluster master role. A VDC administrator can read their storage and work with their volumes and initiator groups. They can read portal groups across the entire cluster; this access is not limited to their VDC.

PrivilegeNumberGranted to
Enable vDC Storage13000Cluster master (global scope required)
iSCSI Create Portal Group13004Cluster master
iSCSI Delete Portal Group13005Cluster master
iSCSI View Portal Group13006Cluster master, VDC administrator (entire cluster)
iSCSI List Portal Groups13007Cluster master, VDC administrator (entire cluster)
Configure vDC Storage iSCSI13009Cluster master
View vDC Storage13010Cluster master, VDC administrator (their VDCs)
List vDC Storages13011Cluster master, VDC administrator (their VDCs)
View vDC Storage iSCSI Detail13026Cluster master, VDC administrator (their VDCs)
Create vDC Volume—Cluster master, VDC administrator (their VDC)
Delete vDC Volume—Cluster master, VDC administrator (their VDC)
Map vDC Volume—Cluster master, VDC administrator (their VDC)
Unmap vDC Volume—Cluster master, VDC administrator (their VDC)
List All Volumes—Cluster master (global scope)
View Storage Overview—Cluster master (global scope)

Privileges 13006 and 13007 do not account for scope, so a VDC administrator can see portal groups for all pools in the cluster. They still cannot create or delete them.

Privileges 13010 and 13011 account for scope: a VDC administrator receives data only for VDCs they are authorized to access. A request for another VDC returns -403 without revealing whether that VDC exists. The same approach protects reads across VDCs: the cluster overview and combined volume table show the topology of all VDCs, so they are unavailable to an individual VDC administrator.

Cluster access overview​

The cluster view is in the Unified Storage section under the cluster node. The Overview tab shows the Protocol Access Overview block — an access funnel with five counts: Initiators → Portal Groups → VDC with Unified Storage → Targets → LUNs. All counts come from a single consistent snapshot, so the funnel levels are arithmetically consistent with one another.

The breakdown is by protocol: in the current version, the screen has one column — iSCSI. A cluster without storage shows a separate message instead of a grid of zeros, while a zero in a nonempty cluster is displayed as "0" — these are different states. A loading error is also distinguishable from "no data".

The section is visible only to the Cluster master role: without cluster overview privileges, the Unified Storage node does not appear in the tree at all.

Cluster portal groups are in the same section, on the Protocols tab → iSCSI selector.

Where to find information​

TaskWhere it is described
Enable VDC storageHow to create a VDC with Unified Storage
Create, read, and delete a volumeVDC volumes
Configure the access point and CHAPConfiguring iSCSI and CHAP
Define who is authorized and through which addressesInitiator and portal groups
Export a volume to a host and remove the mappingConnecting volumes over iSCSI
View the entire clusterThis page, "Cluster access overview" section

Deployment order​

The steps follow a strict sequence, and each step depends on the previous one. The cluster administrator prepares a portal group on the pool in advance: without it, the iSCSI configuration form does not allow you to proceed. Then enable storage on the pool, configure iSCSI, create an initiator group, and only then map volumes.

You can create volumes as soon as storage is enabled — iSCSI is not required for creation; it is required for mapping.

See also​

API methods​

API operations covered on this page: vdc-storage-get, vdc-storage-list, cluster-storage-overview, cluster-list-volumes — see the API reference.